BVT-DLB steam attemperator

Attemperation is used for controlling the degree of superheat in a Heat Recovery Steam Generator (HRSG) or a boiler. Water is injected into the steam pipe using a series of spring loaded atomizing nozzles. Attemperators are installed between the superheater stages in order to protect any secondary superheater pipes from damage owing to excessive heat, called “inter-stage”. Another attemperator is often placed after the boiler / HRSG to regulate the output temperature of the boiler / HRSG or to ensure that the temperature upstream the turbine does not rise too quickly. The BVT-DLB has a welded flow profiling liner for superior evaporation and performance.

Key features

  • Very high reliability due to being able to handle thermal cycling
  • Flow profiling liner as standard
  • Designed to handle large spray water flow
  • Nozzles resistant to flashing
  • Water atomization pressure is maintained at each nozzle at any flow condition
  • Even distribution of spray water in the steam pipe
  • Negligable pressure drop in the steam line

Specifications

Rangeability
Determined by spray water valve

Pressure class
EN PN 16-320
ASME 150-2500

Design temperature
Steam – 630 °C
Water – 250 °C

Materials

Nozzle body/plugInconel 718
SpringHeat resistant spring steel
Steam pipe/linerAdapted to connecting pipe materials
Water pipesX10CrMoVNb91, A-182 F91
13CrMo44, A335-P11 or
St35.8, A105 or
10CrMo9-10, A-335 P22

Nozzles and springs are also available in Inconel for high temperature applications or conditions without water injection.